Effects of key factors on the heat insulation performance of a hollow block ventilated wall
Junchao Huang,
Jinghua Yu and
Hongxing Yang
Applied Energy, 2018, vol. 232, issue C, 409-423
Abstract:
A hollow block ventilated wall can be cooled down in the summer and warmed in the winter by utilizing the air that flows through cavities. The heat transferred between the outdoor and indoor environments can also be removed. However, neither simulations nor experimental studies on the hollow block ventilated wall have been complete, and factors that affect the thermal insulation performance of hollow block ventilated walls need to be identified. In this paper, the frequency-domain finite-difference method and the Number of Transfer Units method are adopted to build the coupled three-dimensional heat transfer model for investigating the temperature distribution on wall surfaces and the exhaust airflow. Experiments are carried out to validate the three-dimensional model, and comparisons prove that the model has considerable accuracy. In addition, both the numerical and experimental studies show that the hollow block ventilated wall can significantly reduce the heat transferred from outdoor environments to indoor rooms through ventilation in the summer. The effects of influential factors, including the airflow velocity, the inlet temperature of the airflow and the cavity size, on the thermal insulation performance of the hollow block ventilated wall are investigated based on the heat transfer model. Results show that the temperature of the inner surface of the hollow block ventilated wall at four orientations is reduced and ranges from 24.8 to 27.0 °C during a typical summer day. The heat flux through the inner surface is reduced by 55.08%, 55.07%, 56.03% and 55.19% respectively for the east, west, south, and north hollow block ventilated walls, indicating the energy saving potential of hollow block ventilated walls. The most critical factor is the cavity size. When the cavity dimension is constant, the influence of the airflow velocity on thermal insulation is much larger compared to the airflow temperature, and the suggested airflow rate is 1.3 m/s. Results show that a higher airflow rate, higher inlet airflow temperature, and larger cavity size, enable the hollow block ventilated wall to achieve better thermal insulation performance.
Keywords: Hollow block ventilated wall; Thermal insulation; Heat transfer; Frequency-domain finite-difference; Thermal comfort; Energy saving (search for similar items in EconPapers)
Date: 2018
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (4)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261918315320
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:232:y:2018:i:c:p:409-423
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2018.09.215
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().