Abstract:
Daylight is a valuable resource with characters of both photometry and radiometry, and window-to-wall ratio (WWR) is a crucial building envelope element that decides the indoor luminous and thermal environments. Due to the traditional utilize of external shadings and lack of appropriate design standard for buildings in China low latitude region, this study proposes a workflow for optimizing WWR with sunshades by considering both daylighting performance and energy consumption. The reference WWR is firstly decided based on the requirements of daylighting standards by using Radiance for standard room without external shading, and the reference annual cooling load of the whole building is then calculated by EnergyPlus. A large number of cases with different WWRs and external shadings are calculated and energy-saving and daylighting performances are finally verified with reference case. The optimal WWR value range with different sunshades configurations in different orientations is that meets daylighting requirement while below reference annual cooling load. The results indicate that comprehensive sunshades have the best energy performance with the benefits of both horizontal and vertical ones. With a 1.8 m comprehensive sunshade, the lower threshold of WWR raises to 0.40 for meeting daylighting requirement, and the accepted upper threshold of WWR range for west, north, east and south-facing units could reach to 0.56, 0.6, 0.6 and 0.78 respectively. For designing a building with façade the same in all orientations, the largest WWR could be set as 0.7 for west-east buildings and 0.55 for south-north buildings with 1.8 m comprehensive sunshades. The scenario has been verified and this WWR optimization process could be applied to different buildings in other climate regions.
Keywords: Window-to-wall ratio (WWR); Sunshades; Daylighting; Energy-saving; Optimization process (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (23)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261918315770
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:233-234:y:2019:i::p:62-70
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2018.10.027
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().