EconPapers    
Economics at your fingertips  
 

Achieving low carbon local energy communities in hot climates by exploiting networks synergies in multi energy systems

Gabriele Comodi, Andrea Bartolini, Francesco Carducci, Balamurugan Nagaranjan and Alessandro Romagnoli

Applied Energy, 2019, vol. 256, issue C

Abstract: Design and planning of low carbon cities and districts must consider the synergies between all the energy networks available. Energy systems optimal design thus assumes a critical importance in determining both costs and environmental impact of operating such districts. This is particularly true following the concept of Local Energy Community, with a single entity representing both the demand and the manager of the energy generation assets. This paper proposes an innovative model for the optimal design of an energy community aiming at lowering its carbon footprint. The community is modeled as a network of spatially dislocated energy hubs, each with its own demand of electricity, heating and cooling energy. The model aims at defining the optimal mix of energy systems, thermal and electric energy storages and energy network infrastructures needed to satisfy the district’s users energy demands. The model is validated using energy demand data from the Nanyang Technological University campus in Singapore by analyzing three scenarios. In the first one, the optimization goal is purely economic and it aims at minimizing the overall cost of operating the district. The second and third scenarios focus on reducing the carbon footprint of the district by imposing an additional constraint, which limits the overall primary energy consumption. In all the scenarios the algorithm chooses to partially or totally connect the five sites with a district cooling network and take advantage of cold thermal storage, proving their potential in hot climates. In the first scenario, the advantages of the district cooling solution are mainly related to the savings in the capital cost of electric chillers that partially offset the cost of the district cooling network; indeed, district cooling network allows the sites to share cooling power thus achieving a reduction in chillers total installed size of 33%.

Keywords: Polygeneration; District planning; District heating and cooling; Distributed generation; Thermal microgrid; Network of multi energy systems (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (24)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261919315880
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:256:y:2019:i:c:s0306261919315880

Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic

DOI: 10.1016/j.apenergy.2019.113901

Access Statistics for this article

Applied Energy is currently edited by J. Yan

More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:appene:v:256:y:2019:i:c:s0306261919315880