EconPapers    
Economics at your fingertips  
 

Implementation and validation of virtual clones of coloured building-integrated photovoltaic facades

Mattia Manni, Tom Melkert, Gabriele Lobaccaro and Bjørn Petter Jelle

Applied Energy, 2025, vol. 378, issue PA, No S0306261924022281

Abstract: A newly introduced colour correction transmittance factor (CCTF) and an innovative probabilistic-to-deterministic approach were applied to create virtual clones of coloured building-integrated photovoltaic (BIPV) systems. These virtual clones calculate the current at maximum power point (Impp) by adjusting the plane-of-array irradiance according to the transmittance properties of the coloured layer, which are governed by the CCTF. An ensemble of 200 randomly combined physical photovoltaic model chains was implemented (probabilistic approach), and the median of the diverse outputs was calculated to provide a deterministic Impp, estimations. The virtual clones were validated against observations from two BIPV facades located in Zwolle (The Netherlands), where black (CCTF=1.00), light-grey (CCTF=0.89), and terracotta (CCTF=0.70) photovoltaic modules were mounted. Hourly Impp data were collected from June 2023 to May 2024. The performance of different regression techniques was evaluated for the calibration of the virtual clones. The non-calibrated virtual clones showed similar accuracy throughout the year, with the determination coefficient (R2) that ranged from 0.594 (light-grey) to 0.613 (terracotta). Although the models generally overestimated Impp, the results demonstrated that such a tendency was accentuated during overcast days. Consistent biases were also observed for solar elevations greater than 30°. Finally, the façade orientation influenced the simulation performance. Indeed, the non-calibrated models overestimated by circa 150 A the annual Impp from the south-facing façade, and by more than 700 A the annual Impp from the façade oriented south-west, regardless of the colour. However, calibration, particularly with Random Forest and Gradient Boosting, consistently reduced cumulative error across all scenarios.

Keywords: Virtual clone; Coloured photovoltaic; Probabilistic analysis; Validation; Building-integrated photovoltaic (search for similar items in EconPapers)
Date: 2025
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261924022281
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:378:y:2025:i:pa:s0306261924022281

Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic

DOI: 10.1016/j.apenergy.2024.124845

Access Statistics for this article

Applied Energy is currently edited by J. Yan

More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:appene:v:378:y:2025:i:pa:s0306261924022281