Spatial distribution characteristics of various physical quantities in PEM fuel cells: Entire morphology investigation based on bifurcated gas distribution zones
Yong Zhang,
Dongjian Zhang,
Yifang Zhang,
Xiaohui Jiang,
Xi Yang,
Jing Cao,
Haoyan Fang,
Qihao Deng,
Ben Chen,
Qingshan Liu and
Yisong Chen
Applied Energy, 2025, vol. 381, issue C, No S0306261924025649
Abstract:
The gas distribution zone (GDZ) plays a crucial role in ensuring the efficient operation of proton exchange membrane fuel cells (PEMFCs), particularly in cells with larger active areas. Its well-considered design effectively mitigates concentration gradients before the gases reach the electrochemical reaction zone, thereby preventing issues such as local oxygen starvation, overheating, and decreased reaction rates that may result from uneven gas distribution. However, suboptimal GDZ design can lead to obstructed gas flow, significant mass distribution disparities, and increased pressure losses. This study conducts a comparative analysis of the overall performance of fuel cells (FCs) with and without the GDZ. The results indicate that in the absence of the GDZ, a significant accumulation of liquid water occurs in the central flow channels, leading to a marked disparity in oxygen molar concentration (OMC) and a 4.6 % reduction in output voltage. Conversely, when the GDZ occupies 21 % of the total area, the average current density (ACD) reaches its peak value, with the electrochemical reaction rate (ERR) and proton conductivity increasing by 1.2 % and 6.8 %, respectively. Additionally, the trends in OMC discrepancies of each flow channel are found to be consistent with those of ACD. Further analysis of the spatial distribution of physical quantities within the empty chamber distribution zone (ECDZ) and the bifurcated distribution zone (BDZ) reveals a significant increase in pressure drop (33.5 %) for the BDZ. Nevertheless, the oxygen value in the gas flow field (GFF) improves by 3.1 %, resulting in a 2.3 % increase in output voltage and a notable mitigation of water flooding issues. The study also explores the relationship between the bending angles of the inner and outer corners of the BDZ. Simulation results suggest that when the inner angle exceeds the outer angle by 10°, an optimal OMC distribution is achieved, leading to a uniform liquid concentration across the entire GFF and the elimination of local water blockages at the outlet of GDZ.
Keywords: PEMFC; GDZ; BDZ; Consistency of mass distribution; Output performance (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261924025649
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:381:y:2025:i:c:s0306261924025649
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2024.125180
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().