Artificial neural networks for energy analysis of office buildings with daylighting
S.L. Wong,
Kevin K.W. Wan and
Tony N.T. Lam
Applied Energy, 2010, vol. 87, issue 2, 557 pages
Abstract:
An artificial neural network (ANN) model was developed for office buildings with daylighting for subtropical climates. A total of nine variables were used as the input parameters - four variables were related to the external weather conditions (daily average dry-bulb temperature, daily average wet-bulb temperature, daily global solar radiation and daily average clearness index), four for the building envelope designs (solar aperture, daylight aperture, overhang and side-fins projections), and the last variable was day type (i.e. weekdays, Saturdays and Sundays). There were four nodes at the output layer with the estimated daily electricity use for cooling, heating, electric lighting and total building as the output. Building energy simulation using EnergyPlus was conducted to generate daily building energy use database for the training and testing of ANNs. The Nash-Sutcliffe efficiency coefficient for the ANN modelled cooling, heating, electric lighting and total building electricity use was 0.994, 0.940, 0.993, and 0.996, respectively, indicating excellent predictive power. Error analysis showed that lighting electricity use had the smallest errors, from 0.2% under-estimation to 3.6% over-estimation, with the coefficient of variation of the root mean square error ranging from 3% to 5.6%.
Keywords: Energy; analysis; Artificial; neural; networks; Daylighting; Office; buildings; Optimisation (search for similar items in EconPapers)
Date: 2010
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (69)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306-2619(09)00266-9
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:87:y:2010:i:2:p:551-557
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().