Impact of roof integrated PV orientation on the residential electricity peak demand
Suresh B. Sadineni,
Fady Atallah and
Robert F. Boehm
Applied Energy, 2012, vol. 92, issue C, 204-210
Abstract:
Peak electricity demand has been an issue in the Desert Southwest region of the US, due to extreme summer temperatures. To address this issue, a consortium was formed between the University of Nevada, Las Vegas, Pulte Homes, and NV Energy. An energy efficient residential community was developed by the team in Las Vegas with approximately 200 homes to study substation-level peak reduction strategies. A summer peak reduction of more than 65%, between 1:00PM and 7:00PM, compared to code standard housing developments is the targeted goal of the project. Approximately 50 homes are already built and some are occupied. The energy performances of the homes have been monitored and are presented in this paper. Several peak electric load reduction strategies such as energy efficiency in buildings, roof integrated photovoltaics (PV) and direct load control have been applied. Though all the homes in the developed community are installed with 1.8kWp PV systems, the orientation of the PV system depends on the building orientation. Focus of this paper is to find the impact of PV orientation on the peak load from a building. In addition, different time-of-use (TOU) energy pricing options are offered by the local electrical utility company. Hence it is important to find an optimal pricing option for each building. A computer model has been developed for one of the homes in the new development using building energy simulation code, ENERGY-10. Calculations on the PV orientations have shown that a south and 220° (i.e. 40° west of due south) orientations are economically optimal for homes enrolled to flat electricity pricing schedule and time of use pricing respectively. As predicted by the simulations, the energy efficiency methods in the home have decreased the total annual energy by 38% compared to a code standard home of the same size. Further, the energy efficiency methods in the building coupled with a 220° oriented PV and 1.1°C increase in thermostat temperature for three hours (from 3:00 to 6:00PM) reduced the peak energy demand by 62% compared to a code standard building of the same size. Battery storage is the other option that will be considered in the project at a later time which is expected to carry the project well beyond its peak reduction goals.
Keywords: PV orientation; Building energy; Peak electric demand; Energy efficient buildings; Peak saving; Energy efficiency (search for similar items in EconPapers)
Date: 2012
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (20)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261911006805
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:92:y:2012:i:c:p:204-210
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic