Modern development of an Adaptive Non-Intrusive Appliance Load Monitoring system in electricity energy conservation
Men-Shen Tsai and
Yu-Hsiu Lin
Applied Energy, 2012, vol. 96, issue C, 55-73
Abstract:
Traditionally, electricity energy consumption of a residence can be monitored through the watt-hour meter installed at the panel. However, the power consumption of individual appliances cannot be identified directly. To track and control the energy consumption of each appliance, many meters are needed. This approach results in high financial costs. To reduce the installation costs, the Non-Intrusive Appliance Load Monitoring (NIALM) approach was proposed recently. In this paper, a novel Adaptive Non-Intrusive Appliance Load Monitoring (ANIALM) system that integrates appliance energizing and de-energizing transient feature extraction methods with soft-computing techniques is developed to keep track of the energy consumption of each appliance. The energizing and de-energizing transient responses of appliances can be captured through the analyses of ANIALM. Two recognizers, k-Nearest Neighbor Rule (k-NNR) and Back-Propagation Artificial Neural Network (BP-ANN), are used to identify different types of appliances and their operation status under different single-load and multiple-load operation scenarios. The Artificial Immune Algorithm (AIA) with the Fisher criterion is employed to adaptively adjust the feature parameters in order to improve the identification performance of recognizers when a new type of appliance is added for monitoring. From the experimental results obtained in different actual environments, the proposed ANIALM system is confirmed that it is able to identify the operation status of appliances. Also, although the generalization of both recognizers is similar and excellent, the k-NNR recognizer used by the ANIALM system is preferred from the aspects of recognizers’ identification mechanism and training performance due to its simplicity in computation and implementation.
Keywords: Artificial Immune Algorithm; Feature extraction; k-Nearest Neighbor Rule; Non-Intrusive Appliance Load Monitoring; Power signatures; Smart grid (search for similar items in EconPapers)
Date: 2012
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (21)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261911007240
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:96:y:2012:i:c:p:55-73
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2011.11.027
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().