The effects of external wall insulation thickness on annual cooling and heating energy uses under different climates
Dongmei Pan,
Mingyin Chan,
Shiming Deng and
Zhongping Lin
Applied Energy, 2012, vol. 97, issue C, 313-318
Abstract:
External wall insulation plays an important role in building energy consumption through affecting cooling and heating energy uses. In this paper, a study on the effects of external wall insulation thickness on annual cooling and heating energy uses under different Chinese climates is reported. Firstly, two indexes: Energy Gain Ratio (EGR) and Relative Variation Ratio (RVR) of the sum of annual cooling and heating energy uses, to assess the effects of external wall insulation thickness on energy saving potential are introduced. Secondly, a model space having four different exterior zones facing four different orientations in an office building is presented and the settings of the model space described. Lastly, the simulated annual cooling and heating energy uses for the four different exterior zones at different external wall insulation thicknesses under three different climates in China, Guangzhou, Shanghai and Beijing, are reported. The results suggested that energy saving was significant by increasing the external wall insulation thickness in exterior zones facing all orientations under Beijing’s climate, since the heating energy use was dominant and can be reduced remarkably with the increase in insulation thickness. Under Shanghai’s climate, increasing external wall insulation thickness to over 26mm would not reduce the sum of annual heating and cooling energy uses in the south-facing exterior zone, but would help save energy in exterior zones facing the other three orientations. For all exterior zones under Guangzhou’s climate, it was, however, hardly possible to reduce the sum of annual heating and cooling energy uses by increasing the external wall insulation thickness.
Keywords: External wall insulation; Annual cooling and heating energy uses; Energy Gain Ratio (EGR); Relative Variation Ratio (RVR) of the sum of annual cooling and heating energy uses; Thickness (search for similar items in EconPapers)
Date: 2012
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (14)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0306261911008038
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:appene:v:97:y:2012:i:c:p:313-318
Ordering information: This journal article can be ordered from
http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/bibliographic
http://www.elsevier. ... 405891/bibliographic
DOI: 10.1016/j.apenergy.2011.12.009
Access Statistics for this article
Applied Energy is currently edited by J. Yan
More articles in Applied Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().