Performance analysis of a water-power combined system with air-heated humidification dehumidification process

W.F. He, X.K. Zhang, D. Han and L. Gao

Energy, 2017, vol. 130, issue C, 218-227

Abstract: Freshwater and power demand are necessary both for the life and production. This paper focus on the water-power combined system, in which the organic Rankine cycle (ORC) is integrated into the air-heated humidification dehumidification (HDH) desalination unit to satisfy the requirements of the freshwater and power coinstantaneously. Mathematical models of the energy balance within the HDH desalination and ORC power subsystem are presented, and the performance of the combined thermal system are demonstrated through numerical simulation. The calculated production of freshwater and power validate the practicability of the proposed combined platform. The simulation results show that peak values for the freshwater production, m˙pw=19.53kgh−1, and gained output ratio (GOR) of the HDH desalination system, GOR = 2.82, are obtained at the balance case, while the maximum power of the ORC subsystem, Wnet = 6.04 kW, arises at m˙sw/m˙da=9. Furthermore, the maximum value of ηWPCS = 94.86% is also obtained at the balance case. It is also illustrated that the elevation of the terminal temperature difference is effective to raise the generated power from the ORC subsystem although the final energy utilization efficiency will be influenced, and the maximum power output is raised from Wnet = 3.33 kW to Wnet = 8.17 kW while the relevant peak value of the total thermal efficiency, ηWPCS decreases from ηWPCS = 109.79% to ηWPCS = 86.89% with the increasing of the terminal temperature difference from ΔTe = 10 K to ΔTe = 20 K. The trend of the freshwater and power variation laws imply that the mass flow rate ratio should be determined according to the actual water and power demand during the design period.

Keywords: Organic Rankine cycle; Humidification dehumidification; Energy balance; Combined thermal system; Gained output ratio (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S036054421730703X
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:130:y:2017:i:c:p:218-227

DOI: 10.1016/j.energy.2017.04.136

Access Statistics for this article

Energy is currently edited by Henrik Lund and Mark J. Kaiser