Transient and thermo-economic analysis of MED-MVC desalination system

Mohamed L. Elsayed, Osama Mesalhy, Ramy H. Mohammed and Louis C. Chow

Energy, 2019, vol. 167, issue C, 283-296

Abstract: An exergo-economic model is used to assess the performance of a multi-effect desalination plant integrated to a mechanical vapor compressor unit (MED-MVC) with a water production capacity of 1500 m3/day. The results show that the second law efficiency (ηII) is 2.8%. The MVC and evaporator units are responsible for about 39 and 52% of the total exergy destruction, respectively. The total water price (TWP) is 1.70 $/m3 when calculated using a simple conventional economic model and 1.63 $/m3 when calculated using an exergy-based cost model. Increasing the number of effects from 1 to 6 results in a 39% reduction in the specific power consumption (SPC), a 70% increase in ηII and a 24% decrease in TWP. A dynamic model is developed to investigate the effect of fluctuations of compressor work (W˙c) and inlet seawater temperature (Tsw) on the plant behavior and performance. The dynamic model results show that the disturbance in W˙c has a significant effect on the plant transient behavior and may cause the plant to cease operation while a disturbance in Tsw has only a moderate impact. Increasing Tsw above a certain value of the steady-state condition without proper control on the plant response could lead to evaporator dry out. In term of performance, a reduction in W˙c causes a decrease in the plant production capacity and SPC, while it increases the plant performance ratio (PR). On the other hand, a reduction in the inlet Tsw causes a reduction in the plant production capacity and PR and an increase in SPC for the same compressor work. Furthermore, a comparison between a MED-MVC system and a MED integrated to a thermal vapor compressor system (MED-TVC) reveals that the latter system is rather sensitive to the reduction in Tsw due to the presence of the condenser unit in the MED-TVC. The response of the MED-MVC system is slower than the MED-TVC which is due to the high thermal capacity of the preheaters for the feed in the MED-MVC.

Keywords: Seawater; Cost diagram; Mechanical vapor compression (MVC); Dynamic disturbance (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0360544218321418
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:167:y:2019:i:c:p:283-296

DOI: 10.1016/j.energy.2018.10.145

Access Statistics for this article

Energy is currently edited by Henrik Lund and Mark J. Kaiser

More articles in Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:energy:v:167:y:2019:i:c:p:283-296