Energy conservation in glass manufacture
T.F. Arican and
Ö. Hortaçsu
Energy, 1992, vol. 17, issue 6, 617-624
Abstract:
Regenerative glass furnaces have continuous glass production but are cyclic in thermal operation. The length of the thermal cycle affects the thermal efficiency of the furnace. We summarize the results of 11 experiments performed on a 33 ton/day end-port type regenerative glass furnace. Six flame-direction reversal times, ranging from 15 to 40 min, were used. The furnace thermal efficiencies were determined to be in the range 41.8–43.8%, with longer flame direction reversal times yielding higher efficiencies. Two alternative methods were used to determine the optimum flame-direction reversal time and both resulted in an optimum cycle time of 40–45 min.
Date: 1992
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/036054429290097J
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:17:y:1992:i:6:p:617-624
DOI: 10.1016/0360-5442(92)90097-J
Access Statistics for this article
Energy is currently edited by Henrik Lund and Mark J. Kaiser
More articles in Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().