Experimental evaluation of an integrated demand response program using electric heat boosters to provide multi-system services
Hanmin Cai,
Andreas Thingvad,
Shi You and
Mattia Marinelli
Energy, 2020, vol. 193, issue C
Abstract:
The share of renewable energy resources (RES) production has been increasing in both the electricity system and the district heating (DH) system in Denmark. This challenges system operators’ traditional operating practices in which different energy systems are separately managed and end-users play a passive role in the system operation. Integrated energy system operation considering multiple energy carriers is increasingly perceived as a key approach to accommodate the RES in a globally optimal way. Although existing literature has analysed (DR)’s potential for improving system operation, it has been largely confined to a single energy system. To fill this gap, the current study focuses on (IDR)’s potential for improving the operation of integrated electricity and DH system. This paper presents one of the first experimental demonstrations of an IDR program by deploying electric heat boosters (EHBs) to provide multi-system services. The multi-scale demonstration of the IDR program was structured into three hierarchical levels: (i) augmented commercial DH substations; (ii) distributed situation-aware control systems; and (iii) an aggregation controller. The results show that EHBs in 5 single-family buildings simultaneously delivered frequency-controlled normal operation reserve (FCR-N) with a symmetric capacity of 7.5 kW to the electricity system with an activation time of 4 s and a peak shaving service to the DH system. The temperature distribution over the test period revealed that end-user comfort was maintained. In conclusion, EHBs in an IDR program can simultaneously support both the electricity system and the DH system, which provides system operators’ a tool for integrated system operation; the multi-system service design enhances the economic outlook of active demands in an IDR program.
Keywords: Integrated demand response; Peak shaving; Frequency-controlled normal operation reserves; Electric heat booster; Low-temperature district heating (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0360544219324247
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:193:y:2020:i:c:s0360544219324247
DOI: 10.1016/j.energy.2019.116729
Access Statistics for this article
Energy is currently edited by Henrik Lund and Mark J. Kaiser
More articles in Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().