Abstract:
Three strategies for solar collector operation are defined. These involve keeping one of the following constant during the day: 1.(i) the average working fluid temperature,2.(ii) the outlet temperature and3.(iii) the inlet temperature. A graphical and analytical method previously developed by the authors was generalized to analyse and compare these strategies. For a constant flow rate, the best strategy is to maintain a constant inlet temperature. A constant outlet temperature is recommended when flow-rate control is possible.