Energy savings in heat-integrated distillation columns
M. Nakaiwa,
K. Huang,
M. Owa,
T. Akiya,
T. Nakane,
Masayuki Sato () and
T. Takamatsu
Energy, 1997, vol. 22, issue 6, 621-625
Abstract:
The heat-integrated distillation column (HIDiC) provides one of the most effective applications of heat-pump technologies to industrial processes. It reinforces a separation process and yields larger energy savings than other methods such as overhead-to-reboiler heat pumps, which involve moving heat between the hottest and coldest points in the distillation column. A simulation study of this column has been applied to the benzene-toluene system to evaluate energy consumption and the required number of stages for comparison with a conventional column. In an example, the total energy requirements were reduced about 60% below those for a conventional column.
Date: 1997
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (10)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0360544296001570
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:22:y:1997:i:6:p:621-625