Costing of a stand-alone photovoltaic system
G. Notton,
M. Muselli and
P. Poggi
Energy, 1998, vol. 23, issue 4, 289-308
Abstract:
We have used a life-cycle cost analysis for a stand-alone photovoltaic system with and without an auxiliary engine generator. Because of different published cost calculations, we apply average values or new estimates in the analysis based on examinations of component lifetimes, maintenance operations, fuel consumption, components costs, percentage of installation completed, and discount rates.
Date: 1998
References: View complete reference list from CitEc
Citations: View citations in EconPapers (7)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0360544297000923
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:23:y:1998:i:4:p:289-308
DOI: 10.1016/S0360-5442(97)00092-3
Access Statistics for this article
Energy is currently edited by Henrik Lund and Mark J. Kaiser
More articles in Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().