Performance analysis of a grid-connected photovoltaic system
M Sidrach-de-Cardona and
Ll Mora López
Energy, 1999, vol. 24, issue 2, 93-102
Abstract:
Grid-connected photovoltaic systems are required to introduce photovoltaic solar energy into urban areas. To analyze these systems, a 2.0 kWp power system has been installed at the University of Málaga, Spain. The array power output was estimated by using measured I–V curves for the installed modules with minimization of mismatch losses. The supplied grid energy and main performances are described. The effects on system yield of threshold-inverter and coupling losses of the inverter to the grid have been studied. During 1997, the system supplied 2678 kWh to the grid, i.e. the mean daily output, was 7.4 kWh. The annual performance ratio was 64.5% and the optimal value 67.9%.
Date: 1999
References: View complete reference list from CitEc
Citations: View citations in EconPapers (10)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S036054429800084X
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:24:y:1999:i:2:p:93-102