Evaluation of the 200 MWe Tonghae CFB boiler performance with cyclone modification
Jong-Min Lee,
Jae-Sung Kim and
Jong-Jin Kim
Energy, 2003, vol. 28, issue 6, 575-589
Abstract:
The performance of the Tonghae CFB boiler with modification of the cyclone has been evaluated using the IEA-CFBC model. The effect of the cyclone efficiency on solid hold-up and pressure and temperature profiles in the combustor has been determined. From the calculated results, solid hold up in the lean phase of the combustor and pressure in the combustor increase, whereas solid hold-up in the dense phase and temperature in the combustor decrease as the cyclone efficiency increases. After modification of the cyclone through extension of the vortex finder and reduction of the width of the cyclone inlet duct, ΔPupper part and ΔPlower part in the combustor increase from 1328 to 1942 Pa and from 4402 to 4950 Pa, respectively. The temperature and the emission of SO2 of the combustor decrease after modification of the cyclone. Therefore, modification of the cyclone to improve its efficiency can allow operation and control of the Tonghae CFB boiler to be stable. The simulation results by the IEA-CFBC model can also explain well the improved performance of the CFB boiler.
Date: 2003
References: View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S036054420200155X
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:28:y:2003:i:6:p:575-589
DOI: 10.1016/S0360-5442(02)00155-X
Access Statistics for this article
Energy is currently edited by Henrik Lund and Mark J. Kaiser
More articles in Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().