EconPapers    
Economics at your fingertips  
 

Direct numerical simulation and CMC (conditional moment closure) sub-model validation of spray combustion

Haiou Wang, Kun Luo and Jianren Fan

Energy, 2012, vol. 46, issue 1, 606-617

Abstract: Direct numerical simulation (DNS) is used to study spray combustion in a slab layer configuration. The gas phase is simulated in an Eulerian way, while the droplets are tracked with a Lagrangian method. The coupling between the two phases is considered. A fourth-order explicit Runge–Kutta method for time integration and an eighth-order central differencing scheme for spatial discretization are used to solve the fully compressible Navier–Stokes (N–S) equation system. One-step reaction mechanism for heptane is adopted. Several cases with different droplet diameters, global equivalence ratios and turbulence intensities are investigated. The general characteristics of spray combustion are described. It is shown that ignition is always found in low scalar dissipation rate regions. Equivalence ratio has the most significant effect on the evolution of spray combustion, while turbulence intensity only has a limited effect. The presumed beta PDF (probability density function) for the mixture fraction is studied, and excellent agreement is found for the predictions and the DNS results. It is demonstrated that the beta PDF is more accurate without evaporation. Conditional moment closure (CMC) sub-models are validated for the scalar dissipation rate, evaporation rate and reaction rate. The scalar dissipation rate is modeled using the amplitude mapping closure (AMC) model. The AMC model has the ability to predict the dissipation rate well except in the rich side. A linear model for evaporate rate captures the correlations of the conditional averaged evaporation rate and the mixture fraction very well for the stoichiometric and fuel-rich cases. Finally, the first-order closure for the reaction rate is examined. It is found that the predictions qualitatively agree with the DNS results at all the timings. The discrepancy is mainly attributed to ignition and extinction in the spray region.

Keywords: Direct numerical simulation; Spray combustion; Conditional moment closure; Sub-model validation (search for similar items in EconPapers)
Date: 2012
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0360544212005968
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:46:y:2012:i:1:p:606-617

DOI: 10.1016/j.energy.2012.07.047

Access Statistics for this article

Energy is currently edited by Henrik Lund and Mark J. Kaiser

More articles in Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:energy:v:46:y:2012:i:1:p:606-617