Sizing, selection, and comparison of heat exchangers considering the lowest saving-investment ratio corresponding to the area at the tag end of the heat exchanger
Ismail Teke,
Özden Ağra,
Hakan Demir and
Ş. Özgür Atayılmaz
Energy, 2014, vol. 78, issue C, 114-121
Abstract:
A new method has been developed to determine the area of waste heat recovery heat exchangers considering the lowest saving-investment ratio corresponding to the area at the tag end of the heat exchanger. Applying this method to any existing heat exchanger, the saving-investment ratio performance considering the area at the tag end of the heat exchanger can also be determined and compared with its optimum value having the same technical and economical parameters. In this study, the distributions of saving-investment ratio in heat exchangers have been obtained based on known technical and economical parameters and NTU (Number of Transfer Units) as d(TYO) = E/Eopt, where Eopt is investment saving potential ratio at optimum, E is local investment-saving potential ratio and dimensionless, which is suggested as “Teke Number” and it is derivatives of effectiveness according to NTU.
Keywords: Effectiveness; NTU; Heat exchangers; Economical; Optimization (search for similar items in EconPapers)
Date: 2014
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0360544214009712
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:energy:v:78:y:2014:i:c:p:114-121
DOI: 10.1016/j.energy.2014.08.035