Abstract:
The paper discusses the effect of an evaporative cooling process and continuous ventilation for improving the indoor conditions of a conventional Thai-style mushroom house. A numerical model describing the behaviour of the Thai-style mushroom house model was developed. It was validated by comparing its output with that of the experiment of a small model of a mushroom house. It was found that the combination of evaporative cooling and continuous ventilation reduced the temperature and increased the relative humidity of air inside a mushroom house that is suitable for growing Lentinus.