Exergy efficiency optimization of photovoltaic and solar collectors’ area in buildings with different heating systems
D. Nikolic,
J. Skerlic,
J. Radulovic,
A. Miskovic,
R. Tamasauskas and
J. Sadauskienė
Renewable Energy, 2022, vol. 189, issue C, 1063-1073
Abstract:
Exergy as a measure of useful work can be used in the design, simulation and performance evaluation of different energy systems. In this paper it is investigated the Serbian residential building with photovoltaics and solar collectors on the roof, and with three different heating systems: electrical heating, district heating and central heating with gas boiler. Exergy optimization was performed with the aim to determine the optimal area of the PV array and solar collectors on the roof (including embodied exergy). With these values, the maximum exergy efficiency of installed solar systems is obtained, and building primary energy consumption is minimized. The residential buildings with variable temperature in domestic hot water system, variable PV cell efficiency and variable hot water consumption are investigated in order to achieve positive-net energy building. The buildings were simulated in EnergyPlus software and Genopt was used for software execution control during optimization. The obtained results show that positive-net energy building with optimally sized photovoltaics and solar collectors’, can be achieved in a case of gas heating system, and in the cases of PV cell efficiency of 14% and 16%. Also, an environmental and economic analysis of the most favourable solutions from exergetic optimization was performed. Total CO2 emission (with embedded emissions of CO2) increases with increasing amount of generated energy – for PV system of cell efficiency of 12%, 14% and 16%, total CO2 emission of solar systems is 20.8 kg CO2/m2, 23.5 kg CO2/m2 and 26.2 kg CO2/m2, respectively. The emission payback time decreases with increasing PV cell efficiency from 1.11 to 1.04 years. With the increase of PV cell efficiency, there is an increase in the annual financial profit (from 1518 to 4305 €), while at the same time, the investment payback period decreases (from 16.9 to 6.1 years). Best results are obtained for the building with gas heating system.
Keywords: Exergy efficiency; Photovoltaic; Solar collector; Building; Optimization (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (3)
Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0960148122003597
Full text for ScienceDirect subscribers only
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:eee:renene:v:189:y:2022:i:c:p:1063-1073
DOI: 10.1016/j.renene.2022.03.075
Access Statistics for this article
Renewable Energy is currently edited by Soteris A. Kalogirou and Paul Christodoulides
More articles in Renewable Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().