Experimental and numerical study on a novel fanless air-to-air solar thermoelectric refrigerator equipped with boosted heat exchanger

Faraz Afshari, Emre Mandev, Burak Muratçobanoğlu, Ali Fatih Yetim and Mehmet Akif Ceviz

Renewable Energy, 2023, vol. 207, issue C, 253-265

Abstract: Peltier cooling systems are generally small, portable and simple in operating principle compared to conventional vapor compression cooling systems. For these reasons, Peltier cooling systems are proposed widely to use in the field. In studies on Peltier coolers presented in the literature, equipment such as pumps and fans is used and this causes noise and vibration. In order to resolve these problems and negative effects, a cooling system was designed and manufactured using completely motionless elements. Additionally, the electricity energy need of this thermoelectric cooling chamber is fully met by solar energy. This study was investigated both experimentally and numerically by using computational fluid dynamics (CFD) methods. By designing a special heat exchanger in the produced air-to-air cooler system, it has been proven that, the Peltier system can work effectively without the need for any elements such as fans. Then the effects of the voltage values applied to the system and the number of Peltier modules have been investigated. The experiments were carried out at 4 different voltage values (1.5, 2.0, 2.5 and 3.0 V) and in 3 different Peltier numbers (1, 3 and 5) in consecutive connections. According to the obtained results, the most suitable situation for reducing the temperature of the cooling chamber were obtained as the voltage was at a maximum of 3 V and the Peltier number was maximum (5 Peltiers mode), where the internal temperature of the cooling chamber decreased to 11.28 °C. It was observed that, the coefficient of performance (COP) values decreased over time in all experiments. Considering the data taken at the beginning of the experiments, the maximum COP value was obtained as 0.04 when 1 Peltier and 1.5 V voltage were applied.

Keywords: Thermoelectric; Coefficient of performance; Heat exchanger; Fanless refrigerator; Renewable energy; Solar cooling (search for similar items in EconPapers)
Date: 2023
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (6)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0960148123002434
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:renene:v:207:y:2023:i:c:p:253-265

DOI: 10.1016/j.renene.2023.02.092

Access Statistics for this article

Renewable Energy is currently edited by Soteris A. Kalogirou and Paul Christodoulides