Energy–exergy analysis and optimization of the solar-boosted Kalina cycle system 11 (KCS-11)

Faming Sun, Weisheng Zhou, Yasuyuki Ikegami, Kenichi Nakagami and Xuanming Su

Renewable Energy, 2014, vol. 66, issue C, 268-279

Abstract: Energy–exergy analysis and parameter design optimization of the KCS-11 solar system with an auxiliary superheater are studied in low-grade thermal energy conversion (LTEC). Firstly, from a thermodynamics point of view, the corresponding calculation model is built to solve the system state points as well as the exergy input/output/loss for each system component. And then, according to the characteristics of the KCS-11 solar system, the verification items are given to verify the correctness of the calculation model. Afterward the model is proved to be correct by sampling check a set of calculation data. On that basis, the corresponding parameter design optimization and system performance analysis are carried out from the viewpoint of the maximization of the exergy output in KCS-11 solar system at a certain scale. Results show that the mass flow rates of working fluid and solar collector subcycle and also ammonia mass fraction are important system operation parameters that should be optimized to deduce the irreversible behavior of the solar system for producing more useful energy. Meanwhile, the heat-transfer rate distribution ratio of the superheater should be large enough to ensure that the expanding vapor in the turbine is superheated. Finally, an optimization calculation case is designed for illustration by using the monthly mean solar radiation statistics in Kumejima Island of Japan. In this case, the maximum generated power is 491kW showing 35.6% exergy efficiency and 6.48% energy efficiency of the system for the month of August. The size of the system in terms of power generated of each major equipment is listed as follows: solar evaporator (370kW), superheater (106kW), condenser (298kW), turbine (491kW), separator (43kW), absorber (37kW), pump (8kW), regenerator (38kW), and diffuser (17kW). And the main system exergy losses are associated with internal consumptions of exergy in turbine (92kW) and condenser (97kW) due to irreversibilities. In this way, the maximum annual power generation of the KCS-11 solar system is about 553,520kWh.

Keywords: KCS-11 solar system; Energy analysis; Exergy analysis; Optimization design; Power generation (search for similar items in EconPapers)
Date: 2014
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (25)

Downloads: (external link)
http://www.sciencedirect.com/science/article/pii/S0960148113006794
Full text for ScienceDirect subscribers only

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:eee:renene:v:66:y:2014:i:c:p:268-279

DOI: 10.1016/j.renene.2013.12.015

Access Statistics for this article

Renewable Energy is currently edited by Soteris A. Kalogirou and Paul Christodoulides

More articles in Renewable Energy from Elsevier
Bibliographic data for series maintained by Catherine Liu ().

 
Page updated 2025-03-19
Handle: RePEc:eee:renene:v:66:y:2014:i:c:p:268-279