Multi-Stage Sensitivity Analysis of the Energy Demand for the Cooling of Grain Warehouses in Cold Regions of China
Hua Zhang,
Junya Ye,
Kunming Li,
Shujie Niu and
Xiao Liu ()
Additional contact information
Hua Zhang: School of Architecture, Henan University of Technology, Zhengzhou 450001, China
Junya Ye: School of Architecture, Henan University of Technology, Zhengzhou 450001, China
Kunming Li: School of Architecture, Henan University of Technology, Zhengzhou 450001, China
Shujie Niu: Department of General Layout Plan and Architecture, Henan University of Technology Design and Research Academy, Zhengzhou 450001, China
Xiao Liu: State Key Laboratory of Subtropical Building and Urban Science, South China University of Technology, Guangzhou 510641, China
Agriculture, 2024, vol. 14, issue 2, 1-15
Abstract:
The early design parameters exert a considerable influence on the cooling energy demand of a granary building in operation. In order to investigate the impact of various parameters on energy use, a grain warehouse energy model was constructed using the Ladybug + Honeybee tools on the Grasshopper platform. Three global energy sensitivity methods were used to analyze the model, and the sizes of the influential parameters were determined and ranked. The study uncovered that the cooling energy demand of the grain warehouse was primarily influenced by factors such as the cooling set-point temperature, roof solar absorptance, roof and exterior wall insulation thickness, window type, and orientation. On this basis, a local sensitivity analysis was conducted for the highly sensitive parameters to identify their influence trend and optimal design range. The results showed that the cooling energy demand of the grain warehouse increases faster as the cooling set-point temperature decreases, with the highest growth rate occurring at a temperature below 18 °C. Lower solar absorptance of the roof is conducive to reducing the cooling energy demand of the grain warehouse. When the thickness of the roof thermal insulation is less than 120 mm and the thickness of the external wall thermal insulation is less than 60 mm, energy use decreases more quickly with greater insulation thickness. It is advisable to use traditional or new windows with thermal insulation and shuttered windows. Furthermore, the optimal position of the long side of the granary was between 10° west and 10° east of north. This research could provide guidance for the energy-saving design and renovation of granary buildings in cold regions of China.
Keywords: design parameters; grain warehouse; global sensitivity analysis; local sensitivity analysis; cooling energy demand (search for similar items in EconPapers)
JEL-codes: Q1 Q10 Q11 Q12 Q13 Q14 Q15 Q16 Q17 Q18 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/2077-0472/14/2/193/pdf (application/pdf)
https://www.mdpi.com/2077-0472/14/2/193/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jagris:v:14:y:2024:i:2:p:193-:d:1327340
Access Statistics for this article
Agriculture is currently edited by Ms. Leda Xuan
More articles in Agriculture from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().