EconPapers    
Economics at your fingertips  
 

Rapid and High-Performance Analysis of Total Nitrogen in Coco-Peat Substrate by Coupling Laser-Induced Breakdown Spectroscopy with Multi-Chemometrics

Bing Lu, Xufeng Wang, Can Hu and Xiangyou Li ()
Additional contact information
Bing Lu: Wuhan National Laboratory for Optoelectronics (WNLO), Huazhong University of Science and Technology (HUST), Wuhan 430074, China
Xufeng Wang: College of Mechanical and Electrical Engineering, Tarim University, Alar 843300, China
Can Hu: College of Mechanical and Electrical Engineering, Tarim University, Alar 843300, China
Xiangyou Li: Wuhan National Laboratory for Optoelectronics (WNLO), Huazhong University of Science and Technology (HUST), Wuhan 430074, China

Agriculture, 2024, vol. 14, issue 6, 1-17

Abstract: Nitrogen is an important nutrient element for crop growth. Rapid and accurate acquisition of nitrogen content in cultivation substrate is the key to precise fertilization. In this study, laser-induced breakdown spectroscopy (LIBS) was used to detect the total nitrogen (TN) of coco-peat substrate. A LIBS spectrum acquisition system was established to collect the spectral line signal of samples with wavelengths ranging from 200 nm to 860 nm. Synergy interval partial least squares (Si-PLS) algorithm and elimination of uninformative variables (UVE) algorithm were used to select the spectral data of TN characteristic lines in coco-peat substrate. Univariate calibration curve and partial least squares regression (PLSR) were used to build mathematical models for the relationship between the spectral data of univariate characteristic spectral lines, full variables and screened multi-variable characteristic spectral lines of samples and reference measurement values of TN. By comparing the detection performance of calibration curves and multivariate spectral prediction models, it was concluded that UVE was used to simplify the number of spectral input variables for the model and PLSR was applied to construct the simplest multivariate model for the measurement of TN in the substrate samples. The model provided the best measurement performance, with the calibration set determination coefficient ( R C 2 ) and calibration set root mean square error (RMSEC) values of 0.9944 and 0.0382%, respectively; the prediction set determination coefficient ( R P 2 ) and prediction set root mean square error (RMSEP) had values of 0.9902 and 0.0513%, respectively. These results indicated that the combination of UVE and PLSR could make full use of the variable information related to TN detection in the LIBS spectrum and realize the rapid and high-performance measurement of TN in coco-peat substrate. It would provide a reference for the rapid and quantitative assessment of nutrient elements in other substrate and soil.

Keywords: coco-peat substrate; total nitrogen; laser-induced breakdown spectroscopy; synergy interval partial least squares; uninformative variables elimination (search for similar items in EconPapers)
JEL-codes: Q1 Q10 Q11 Q12 Q13 Q14 Q15 Q16 Q17 Q18 (search for similar items in EconPapers)
Date: 2024
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/2077-0472/14/6/946/pdf (application/pdf)
https://www.mdpi.com/2077-0472/14/6/946/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jagris:v:14:y:2024:i:6:p:946-:d:1416550

Access Statistics for this article

Agriculture is currently edited by Ms. Leda Xuan

More articles in Agriculture from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jagris:v:14:y:2024:i:6:p:946-:d:1416550