EconPapers    
Economics at your fingertips  
 

Calibrating Parameters for Microsimulation Disease Models

Alex van der Steen, Joost van Rosmalen, Sonja Kroep, Frank van Hees, Ewout W. Steyerberg, Harry J. de Koning, Marjolein van Ballegooijen and Iris Lansdorp-Vogelaar

Medical Decision Making, 2016, vol. 36, issue 5, 652-665

Abstract: Background. Calibration (estimation of model parameters) compares model outcomes with observed outcomes and explores possible model parameter values to identify the set of values that provides the best fit to the data. The goodness-of-fit (GOF) criterion quantifies the difference between model and observed outcomes. There is no consensus on the most appropriate GOF criterion, because a direct performance comparison of GOF criteria in model calibration is lacking. Methods. We systematically compared the performance of commonly used GOF criteria (sum of squared errors [SSE], Pearson chi-square, and a likelihood-based approach [Poisson and/or binomial deviance functions]) in the calibration of selected parameters of the MISCAN-Colon microsimulation model for colorectal cancer. The performance of each GOF criterion was assessed by comparing the 1) root mean squared prediction error (RMSPE) of the selected parameters, 2) computation time of the calibration procedure of various calibration scenarios, and 3) impact on estimated cost-effectiveness ratios. Results. The likelihood-based deviance resulted in the lowest RMSPE in 4 of 6 calibration scenarios and was close to best in the other 2. The SSE had a 25 times higher RMSPE in a scenario with considerable differences in the values of observed outcomes, whereas the Pearson chi-square had a 60 times higher RMSPE in a scenario with multiple studies measuring the same outcome. In all scenarios, the SSE required the most computation time. The likelihood-based approach estimated the cost-effectiveness ratio most accurately (up to −0.15% relative difference versus 0.44% [SSE] and 13% [Pearson chi-square]). Conclusions. The likelihood-based deviance criteria lead to accurate estimation of parameters under various circumstances. These criteria are recommended for calibration in microsimulation disease models in contrast with other commonly used criteria.

Keywords: model calibration; microsimulation modeling; cancer screening; goodness-of-fit criterion (search for similar items in EconPapers)
Date: 2016
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://journals.sagepub.com/doi/10.1177/0272989X16636851 (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:sae:medema:v:36:y:2016:i:5:p:652-665

DOI: 10.1177/0272989X16636851

Access Statistics for this article

More articles in Medical Decision Making
Bibliographic data for series maintained by SAGE Publications ().

 
Page updated 2025-03-19
Handle: RePEc:sae:medema:v:36:y:2016:i:5:p:652-665