EconPapers    
Economics at your fingertips  
 

Three-dimensional cerebrospinal fluid flow within the human ventricular system

L. Howden, D. Giddings, H. Power, A. Aroussi, M. Vloeberghs, M. Garnett and D. Walker

Computer Methods in Biomechanics and Biomedical Engineering, 2008, vol. 11, issue 2, 123-133

Abstract: Cerebrospinal fluid (CSF) is a Newtonian fluid and can, therefore, be modelled using computational fluid dynamics (CFD). Previous modelling of the CSF has been limited to simplified geometric models. This work describes a geometrically accurate three dimensional (3D) computational model of the human ventricular system (HVS) constructed from magnetic resonance images (MRI) of the human brain. It is an accurate and full representation of the HVS and includes appropriately positioned CSF production and drainage locations. It was used to investigate the pulsatile motion of CSF within the human brain. During this investigation CSF flow rate was set at a constant 500 ml/day, to mimic real life secretion of CSF into the system, and a pulsing velocity profile was added to the inlets to incorporate the effect of cardiac pulsations on the choroid plexus and their subsequent influence on CSF motion in the HVS. Boundary conditions for the CSF exits from the ventricles (foramina of Magendie and Lushka) were found using a “nesting” approach, in which a simplified model of the entire central nervous system (CNS) was used to examine the effects of the CSF surrounding the ventricular system (VS). This model provided time varying pressure data for the exits from the VS nested within it. The fastest flow was found in the cerebral aqueduct, where a maximum velocity of 11.38 mm/s was observed over five cycles. The maximum Reynolds number recorded during the simulation was 15 with an average Reynolds number of the order of 0.39, indicating that CSF motion is creeping flow in most of the computational domain and consequently will follow the geometry of the model. CSF pressure also varies with geometry with a maximum pressure drop of 1.14 Pa occurring through the cerebral aqueduct. CSF flow velocity is substantially slower in the areas that are furthest away from the inlets; in some areas flow is nearly stagnant.

Date: 2008
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255840701492118 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:11:y:2008:i:2:p:123-133

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255840701492118

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:11:y:2008:i:2:p:123-133