EconPapers    
Economics at your fingertips  
 

Improved execution efficiency of model-based roentgen stereophotogrammetric analysis: simplification and segmentation of model meshes

Ci-Bin Syu, Shang-Chih Lin, Chung-Yi Huang, Jiing-Yih Lai, Kao-Shang Shih and Kuo-Jen Chen

Computer Methods in Biomechanics and Biomedical Engineering, 2012, vol. 15, issue 12, 1347-1357

Abstract: Recently, the model-based roentgen stereophotogrammetric analysis (RSA) method has been developed as an in vivo tool to estimate static pose and dynamic motion of the instrumented prostheses. The two essential inputs for the RSA method are prosthetic models and roentgen images. During RSA calculation, the implants are often reversely scanned and input in the form of meshes to estimate the outline error between prosthetic projection and roentgen images. However, the execution efficiency of the RSA iterative calculation may limit its clinical practicability, and one reason for inefficiency may be very large number of meshes in the model. This study uses two methods of mesh manipulation to improve the execution efficiency of RSA calculation. The first is to simplify the model meshes and the other is to segment and delete the meshes of insignificant regions. An index (i.e. critical percentage) of an optimal element number is defined as the trade-off between execution efficiency and result accuracy. The predicted results are numerically validated by total knee prosthetic system. The outcome shows that the optimal strategy of the mesh manipulation is simplification and followed by segmentation. On average, the element number can even be reduced to 1% of the original models. After the mesh manipulation, the execution efficiency can be increased about 75% without compromising the accuracy of the predicted RSA results (the increment of rotation and translation error: 0.06° and 0.02 mm). In conclusion, prosthetic models should be manipulated by simplification and segmentation methods prior to the RSA calculation to increase the execution efficiency and then to improve clinical applicability of the RSA method.

Date: 2012
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2011.597352 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:15:y:2012:i:12:p:1347-1357

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2011.597352

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:15:y:2012:i:12:p:1347-1357