Integration of geometric separation mechanisms by implementing curved constrictions in a biochip microchannel fluidic separator
Xiangdong Xue and
Chris Bailey
Computer Methods in Biomechanics and Biomedical Engineering, 2013, vol. 16, issue 3, 314-327
Abstract:
This paper investigates the effectiveness of using curved constrictions in the bifurcation region of T-type fluid separators for promoting flow development in the intervals between bifurcations. A design of biofluid separator is proposed and a mathematical analysis and a numerical simulation of the blood flow in microchannels are conducted. The design is based on a modification of an existing T-shaped biochip device which consists of a main channel and a series of perpendicularly positioned side channels. By means of bifurcation effect, the blood is separated into plasma concentration flow from the side channels and blood cell concentration flow from the main channel. In this design, curved constrictions are inserted between bifurcations to replace the original straight channel section, so that the constriction and curved channel effects can be induced apart from the existing bifurcation effect. The mathematical analysis is aimed to the flow field and shear stress of the blood fluid in the microchannel geometries employed in the current design, including bifurcation, constriction and curved channel. The numerical simulation and mathematical analysis result in agreed conclusions, giving some insights into the importance of the relevant geometries in promoting biofluid separation. The main results can be summarised as follows: (i) the constrictions can largely increase the shear stress by the ratio of square of the reduction of the sections between the constriction and parent main channel. (ii) The curved channel intervals can induce centrifugal force, smoothly transit the flow field and increase the chances depleting fluid from the cell-free layer. (iii) The thickness of the boundary layer skimmed into the side channels from the main channel is decreased in this design and can be controlled, falling into the cell-free layer region by adjusting the geometry of the side channels.
Date: 2013
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2011.618927 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:16:y:2013:i:3:p:314-327
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2011.618927
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().