Automated pelvic anatomical coordinate system is reproducible for determination of anterior pelvic plane

Shinya Hayashi, Takayuki Nishiyama, Takaaki Fujishiro, Noriyuki Kanzaki, Nao Shibanuma, Syoji Kobashi and Masahiro Kurosaka

Computer Methods in Biomechanics and Biomedical Engineering, 2013, vol. 16, issue 9, 937-942

Abstract: Most of computer-assisted planning systems need to determine the anatomical axis based on the anterior pelvic plane (APP). We analysed that our new system is more reproducible for determination of APP than previous methods. A pelvic model bone and two subjects suffering from hip osteoarthritis were evaluated. Multidetector-row computed tomography (MDCT) images were scanned with various rotations by MDCT scanner. The pelvic rotation was calibrated using silhouette images. APP was determined by an optimisation technique. The values of variation of APP caused by pelvic rotation were analysed with statistical analysis. APP determination with calibration and optimisation was most reproducible.The values of variance of APP were within 0.05° in model bone and 0.2° even in patient pelvis. Furthermore, the values of variance of APP with calibration/optimisation were significantly lower in comparison without calibration/optimisation. Both calibration and optimisation are actually required for determination of APP. This system could contribute to the evaluation of hip joint kinematics and computer-assisted surgery.

Date: 2013
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2011.644541 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:16:y:2013:i:9:p:937-942

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2011.644541

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:16:y:2013:i:9:p:937-942