Determination of expander apparatus displacements and contact pressures on the mucosa using FEM modelling considering mandibular asymmetries
Iracema Utsch Braga,
Daniel Neves Rocha,
Ricardo Luiz Utsch,
Estevam Barbosa Las Casas,
Roberto Márcio Andrade,
Renato Natal Jorge and
Rafael Utsch Braga
Computer Methods in Biomechanics and Biomedical Engineering, 2013, vol. 16, issue 9, 954-962
Abstract:
This paper presents a method for prediction of forces and displacements in the expansion screw of a modified mandibular Schwarz appliance and the contact pressure distributions on the mucosa during malocclusions treatment. A 3D finite element biomechanical model of the complete mandible–mucosa–apparatus set was built using computerised tomographic images of a patient's mandible and constructive solid geometry by computer software. An iterative procedure was developed to handle a boundary condition that takes into account the mandibular asymmetries. The results showed asymmetries in the contact pressure distributions that indicated with precision the patient's malocclusion diagnosis. In vivo measurements of contact pressure using piezoelectric sensors agreed with the computational results. It was shown that the left and right ends of the expansion screw move differently with respect to the patient mandible, even though the expansion screw has an opening mechanism to ensure equal stretching at both ends. The contact pressures between the apparatus and the mucosa vary linearly with applied forces, which can simplify the analysis of the biomechanical behaviour of the expander mandible apparatus. The biomechanical modelling proposed in this paper can be a useful tool to improve malocclusions treatment, safely avoiding the use of forces acting on live structures beyond the biological tolerance, which could result in traumatic effects.
Date: 2013
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2011.645227 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:16:y:2013:i:9:p:954-962
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2011.645227
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().