Computational framework to model and design surgical meshes for hernia repair
B. Hernández-Gascón,
N. Espés,
E. Peña,
G. Pascual,
J.M. Bellón and
B. Calvo
Computer Methods in Biomechanics and Biomedical Engineering, 2014, vol. 17, issue 10, 1071-1085
Abstract:
Surgical procedures for hernia surgery are usually performed using prosthetic meshes. In spite of all the improvements in these biomaterials, the perfect match between the prosthesis and the implant site has not been achieved. Thus, new designs of surgical meshes are still being developed. Previous to implantation in humans, the validity of the meshes has to be addressed, and to date experimental studies have been the gold standard in testing and validating new implants. Nevertheless, these procedures involve long periods of time and are expensive. Thus, a computational framework for the simulation of prosthesis and surgical procedures may overcome some disadvantages of the experimental methods. The computational framework includes two computational models for designing and validating the behaviour of new meshes, respectively. Firstly, the beam model, which reproduces the exact geometry of the mesh, is set to design the weave and determine the stiffness of the surgical prosthesis. However, this implies a high computational cost whereas the membrane model, defined within the framework of the large deformation hyperelasticity, is a relatively inexpensive computational tool, which also enables a prosthesis to be included in more complex geometries such as human or animal bodies.
Date: 2014
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2012.736967 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:17:y:2014:i:10:p:1071-1085
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2012.736967
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().