EconPapers    
Economics at your fingertips  
 

Self-expanding stent modelling and radial force accuracy

Ríona Ní Ghriallais and Mark Bruzzi

Computer Methods in Biomechanics and Biomedical Engineering, 2014, vol. 17, issue 4, 318-333

Abstract: Computational simulations using finite element analysis are a tool commonly used to analyse stent designs, deployment geometries and interactions between stent struts and arterial tissue. Such studies require large computational models and efforts are often made to simplify models in order to reduce computational time while maintaining reasonable accuracy. The objective of the study is focused on computational modelling and specifically aims to investigate how different methods of modelling stent–artery interactions can affect the results, computational time taken and computational size of the model. Various different models, each with increasing levels of complexity, are used to simulate this analysis, representing the many assumptions and simplifications used in other similar studies in order to determine what level of simplification will still allow for an accurate representation of stent radial force and resulting stress concentrations on the inner lining of the vessel during self-expanding stent deployment. The main conclusions of the study are that methods used in stent crimping impact on the resulting predicted radial force of the stent; that accurate representation of stent–artery interactions can only be made when modelling the full length of the stent due to the incorporation of end effects; and that modelling self-contact of the stent struts greatly impacts on the resulting stress concentrations within the stent, but that the effect of this on the unloading behaviour and resulting radial force of the stent is negligible.

Date: 2014
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2012.683427 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:17:y:2014:i:4:p:318-333

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2012.683427

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:17:y:2014:i:4:p:318-333