Electrocardiogram signal quality assessment using an artificially reconstructed target lead
H. Naseri and
M.R. Homaeinezhad
Computer Methods in Biomechanics and Biomedical Engineering, 2015, vol. 18, issue 10, 1126-1141
Abstract:
In real applications, even the most accurate electrocardiogram (ECG) analysis algorithm, based on research databases, might breakdown completely if a quality measurement technique is not applied precisely before the analysis. The major concentration of this study is to describe and develop a reliable ECG signal quality assessment technique. The proposed algorithm includes three major stages: preprocessing, energy-concavity index (ECI) analysis and a correlation-based examination subroutine. The preprocessing step includes the removal of baseline wanders and high-frequency disturbances. The quality measurement based on ECI includes two separate stages according to the energy and concavity of the ECG signal. The correlation-based quality measurement step is mainly established by using the correlation between ECG leads estimated by applying a suitably trained neural network. The operating characteristics of the proposed ECI are sensitivity (Se) of 77.04% with a positive predictive value (PPV) of 90.53% for detecting high-energy noise. The correlation-based technique achieved the best scores (Se = 100%; PPV = 98.92%) for detecting high-energy noise and for recognising any other kind of disturbances (Se = 92.36%; PPV = 94.77%). Although ECI analysis acts effectively against high-energy disturbances, very poor performance is obtained in cases where the energy of the disturbances is not considerable. However, the correlation-based method is able to find all kinds of disturbances. For officially evaluating the proposed algorithm, an entry was sent to the Computing-in-Cardiology Challenge 2011 on 27 February 2012; a final score (accuracy) of 93.60% was achieved.
Date: 2015
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2013.875163 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:18:y:2015:i:10:p:1126-1141
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2013.875163
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().