EconPapers    
Economics at your fingertips  
 

Systolic fluid–structure interaction model of the congenitally bicuspid aortic valve: assessment of modelling requirements

May Y.S. Kuan and Daniel M. Espino

Computer Methods in Biomechanics and Biomedical Engineering, 2015, vol. 18, issue 12, 1305-1320

Abstract: A transient fluid–structure interaction (FSI) model of a congenitally bicuspid aortic valve has been developed which allows simultaneous calculation of fluid flow and structural deformation. The valve is modelled during the systolic phase (the stage when blood pressure is elevated within the heart to pump blood to the body). The geometry was simplified to represent the bicuspid aortic valve in two dimensions. A congenital bicuspid valve is compared within the aortic root only and within the aortic arch. Symmetric and asymmetric cusps were simulated, along with differences in mechanical properties. A moving arbitrary Lagrange–Euler mesh was used to allow FSI. The FSI model requires blood flow to induce valve opening and induced strains in the region of 10%. It was determined that bicuspid aortic valve simulations required the inclusion of the ascending aorta and aortic arch. The flow patterns developed were sensitive to cusp asymmetry and differences in mechanical properties. Stiffening of the valve amplified peak velocities, and recirculation which developed in the ascending aorta. Model predictions demonstrate the need to take into account the category, including any existing cusp asymmetry, of a congenital bicuspid aortic valve when simulating its fluid flow and mechanics.

Date: 2015
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2014.900663 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:18:y:2015:i:12:p:1305-1320

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2014.900663

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:18:y:2015:i:12:p:1305-1320