Quantification of trabecular spatial orientation from low-resolution images
L. Lenaerts,
A.J. Wirth and
G.H. van Lenthe
Computer Methods in Biomechanics and Biomedical Engineering, 2015, vol. 18, issue 13, 1392-1399
Abstract:
No accepted methodology exists to assess trabecular bone orientation from clinical CT scans. The aim of this study was to test the hypothesis that the distribution of grey values in clinical CT images is related to the underlying trabecular architecture and that this distribution can be used to identify the principal directions and local anisotropy of trabecular bone. Fourteen trabecular bone samples were extracted from high-resolution (30 μm) micro-CT scans of seven human femoral heads. Trabecular orientations and local anisotropy were calculated using grey-level deviation (GLD), a novel method providing a measure of the three-dimensional distribution of image grey values. This was repeated for different image resolutions down to 300 μm and for volumes of interest (VOIs) ranging from 1 to 7 mm. Outcomes were compared with the principal mechanical directions and with mean intercept length (MIL) as calculated for the segmented 30-μm images. For the 30-μm images, GLD predicted the mechanical principal directions equally well as MIL. For the 300-μm images, which are resolutions that can be obtained in vivo using clinical CT, only a small increase (3°–6°) in the deviation from the mechanical orientations was found. VOIs of 5 mm resulted in a robust quantification of the orientation. We conclude that GLD can quantify structural bone parameters from low-resolution CT images.
Date: 2015
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2014.908856 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:18:y:2015:i:13:p:1392-1399
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2014.908856
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().