EconPapers    
Economics at your fingertips  
 

Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformation

Izabela Lubowiecka

Computer Methods in Biomechanics and Biomedical Engineering, 2015, vol. 18, issue 3, 223-232

Abstract: Surgical implants used in hernia repair reveal isotropic as well as orthotropic properties. In particular, its orthotropy, in relation to the different range of typical deformations observed in different directions and zones of abdomen surface due to the patients' life activities, has a significant influence on the extreme junction forces in the mesh–tissue connections and hence the repair persistence. The finite element model of the orthotropic implant was developed, and the junction forces in the connections of tissue and mesh were studied. The kinematical extortions representing the abdomen surface deformations identified in specific zones of hernia placement were applied to the model. The sensitive analysis was applied to specify the influence of the orthotropy (implant orientation) direction to the repair persistence. Due to the anisotropy of the human abdomen and also the different range of deformations observed in different areas of abdomen surface, the behaviour of the implant differs significantly depending on the hernia placement and the implant orientation. Especially, it is observed in the values of the implant–tissue junction forces which determinate considerably the repair persistence. The provided results and conclusions may be useful in some clinical recommendations for implantation of orthotropic surgical mesh specifying the hernia placement as well as the orthotropic implant orientation. This can also be considered in the design of new synthetic implants with more physiologic tissue-like properties also taking into account the human abdomen anisotropy.

Date: 2015
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2013.789102 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:18:y:2015:i:3:p:223-232

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2013.789102

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:18:y:2015:i:3:p:223-232