A porohyperelastic finite element model of the eye: the influence of stiffness and permeability on intraocular pressure and optic nerve head biomechanics

Avinash Ayyalasomayajula, Robert I. Park, Bruce R. Simon and Jonathan P. Vande Geest

Computer Methods in Biomechanics and Biomedical Engineering, 2016, vol. 19, issue 6, 591-602

Abstract: Progressively deteriorating visual field is a characteristic feature of primary open-angle glaucoma (POAG), and the biomechanics of optic nerve head (ONH) is believed to be important in its onset. We used porohyperelasticity to model the complex porous behavior of ocular tissues to better understand the effect variations in ocular material properties can have on ONH biomechanics. An axisymmetric model of the human eye was constructed to parametrically study how changes in the permeabilities of retina–Bruch's–choroid complex \[( k _{RBC})\] (kRBC), sclera \[( k _{sclera})\] (ksclera), uveoscleral pathway \[( k _{UVSC})\] (kUVSC), and trabecular meshwork \[( k _{TM})\] (kTM) as well as how changes in the stiffness of the lamina cribrosa (LC) and sclera affect IOP, LC strains, and translaminar interstitial pressure gradients (TLIPG). Decreasing \[k _{RBC}\] kRBC from 5 × 10− 12 to 5 × 10− 13 m/s increased IOP and LC strains by 17%, and TLIPG by 21%. LC strains increased by 13% and 9% when the scleral and LC moduli were decreased by 48% and 50%, respectively. In addition to the trabecular meshwork and uveoscleral pathway, the retina–Bruch's–choroid complex had an important effect on IOP, LC strains, and TLIPG. Changes in \[k _{RBC}\] kRBC and scleral modulus resulted in nonlinear changes in the IOP, and LC strains especially at the lowest \[k _{TM}\] kTM and \[k _{UVSC}\] kUVSC. This study demonstrates that porohyperelastic modeling provides a novel method for computationally studying the biomechanical environment of the ONH. Porohyperelastic simulations of ocular tissues may help provide further insight into the complex biomechanical environment of posterior ocular tissues in POAG.

Date: 2016
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2015.1052417 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:19:y:2016:i:6:p:591-602

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2015.1052417

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:19:y:2016:i:6:p:591-602