Computational analysis of pediatric ventricular assist device implantation to decrease cerebral particulate embolization
ThuyTien Nguyen,
I. Ricardo Argueta-Morales,
Stephen Guimond,
William Clark,
Andres Ceballos,
Ruben Osorio,
Eduardo A. Divo,
William M. De Campli and
Alain J. Kassab
Computer Methods in Biomechanics and Biomedical Engineering, 2016, vol. 19, issue 7, 789-799
Abstract:
Stroke is the most devastating complication after ventricular assist device (VAD) implantation with a 19% incidence and 65% mortality in the pediatric population. Current pediatric VAD technology and anticoagulation strategies alone are suboptimal. VAD implantation assisted by computational methods (CFD) may contribute reducing the risk of cerebral embolization. Representative three-dimensional aortic arch models of an infant and a child were generated. An 8 mm VAD outflow-graft (VAD-OG) anastomosed to the aorta was rendered and CFD was applied to study blood flow patterns. Particle tracks, originating in the VAD, were computed with a Lagrangian phase model and the percentage of particles entering the cerebral vessels was calculated. Eight implantation configurations (infant = 5 and child = 3) and 5 particle sizes (0.5, 1, 2, 3, and 4 mm) were considered. For the infant model, percentage of particles entering the cerebral vessels ranged from 15% for a VAD-OG anastomosed at 90° to the aorta, to 31% for 30° VAD-OG anastomosis (overall percentages: X2 = 10,852, p < 0.0001). For the child model, cerebral embolization ranged from 9% for the 30° VAD-OG anastomosis to 15% for the 60° anastomosis (overall percentages: χ2 = 10,323, p < 0.0001). Using detailed CFD calculations, we demonstrate that the risk of stroke depends significantly on the VAD implantation geometry. In turn, the risk probably depends on patient-specific anatomy. CFD can be used to optimize VAD implantation geometry to minimize stroke risk.
Date: 2016
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2015.1062478 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:19:y:2016:i:7:p:789-799
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2015.1062478
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().