EconPapers    
Economics at your fingertips  
 

Numerical study of intrathecal drug delivery to a permeable spinal cord: effect of catheter position and angle

G. Pizzichelli, B. Kehlet, Ø. Evju, B. A. Martin, M. E. Rognes, K. A. Mardal and E. Sinibaldi

Computer Methods in Biomechanics and Biomedical Engineering, 2017, vol. 20, issue 15, 1599-1608

Abstract: Intrathecal delivery is a procedure involving the release of therapeutic agents into the cerebrospinal fluid (CSF) hrough a catheter. It holds promise for treating high-impact central nervous system pathologies, for which systemic administration routes are ineffective. In this study we introduce a numerical model able to simultaneously account for solute transport in the fluid and in the spinal cord. Using a Discontinuous Galerkin method and a three-dimensional patient-specific geometry, we studied the effect of catheter position and angle on local spinal cord drug concentration. We considered twenty cardiac cycles to limit the computational cost of our approach, which resolves the physics both in space and time. We used clinically representative data for the drug injection speed and dose rate, and scaled drug diffusion/penetration properties to obtain observable effects during the considered simulation time. Based on our limited set of working parameters, lateral injection perpendicular to the cord turned out to be more effective than other configurations. Even if the adopted scaling does not allow for a direct clinical translation (a wider parametric assessment of the importance of CSF flow, geometry and diffusion properties is needed), it did not weaken our numerical approach, which can be used to systematically investigate multiple catheter, geometry and fluid/tissue properties configurations, thus paving the way for therapy control.

Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2017.1393805 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:20:y:2017:i:15:p:1599-1608

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2017.1393805

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:20:y:2017:i:15:p:1599-1608