A new formulation of slight compressibility for arterial tissue and its Finite Element implementation
M. D. Gilchrist,
D. MacManus,
J. G. Murphy and
B. Pierrat
Computer Methods in Biomechanics and Biomedical Engineering, 2017, vol. 20, issue 4, 403-414
Abstract:
In order to avoid the numerical difficulties in locally enforcing the incompressibility constraint using the displacement formulation of the Finite Element Method, slight compressibility is typically assumed when simulating the mechanical response of arterial tissue. The current standard method of accounting for slight compressibility of hyperelastic soft tissue assumes an additive decomposition of the strain-energy function into a volumetric and a deviatoric part. This has been shown, however, to be inconsistent with the linear theory and results in cubes retaining their cuboid shape under hydrostatic tension and compression, which seems at variance with the reinforcement of arterial tissue with two families of collagen fibres. A remedy for these defects is proposed here, a solution which generalises the current standard model of slight compressibility to include two additional terms, one of which is quadratic in the I4,I6$ I_4, I_6 $ invariants and the other quadratic in I8$ I_8 $. Experimental data are used to motivate typical values for the associated material constants of these additional terms. Some simulations are performed to allow contrasts and comparisons to be made between the current standard model of slight compressibility and its generalisation proposed here.
Date: 2017
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2016.1236371 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:20:y:2017:i:4:p:403-414
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2016.1236371
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().