EconPapers    
Economics at your fingertips  
 

Across-subject calibration of an instrumented glove to measure hand movement for clinical purposes

Verónica Gracia-Ibáñez, Margarita Vergara, James H. Buffi, Wendy M. Murray and Joaquín L. Sancho-Bru

Computer Methods in Biomechanics and Biomedical Engineering, 2017, vol. 20, issue 6, 587-597

Abstract: Motion capture of all degrees of freedom of the hand collected during performance of daily living activities remains challenging. Instrumented gloves are an attractive option because of their higher ease of use. However, subject-specific calibration of gloves is lengthy and has limitations for individuals with disabilities. Here, a calibration procedure is presented, consisting in the recording of just a simple hand position so as to allow capture of the kinematics of 16 hand joints during daily life activities even in case of severe injured hands. ‘across-subject gains’ were obtained by averaging the gains obtained from a detailed subject-specific calibration involving 44 registrations that was repeated three times on multiple days to 6 subjects. In additional 4 subjects, joint angles that resulted from applying the ‘across-subject calibration’ or the subject-specific calibration were compared. Global errors associated with the ‘across-subject calibration’ relative to the detailed, subject-specific protocol were small (bias: 0.49°; precision: 4.45°) and comparable to those that resulted from repeating the detailed protocol with the same subject on multiple days (0.36°; 3.50°). Furthermore, in one subject, performance of the ‘across-subject calibration’ was directly compared to another fast calibration method, expressed relative to a videogrammetric protocol as a gold-standard, yielding better results.

Date: 2017
References: Add references at CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2016.1265950 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:20:y:2017:i:6:p:587-597

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2016.1265950

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:20:y:2017:i:6:p:587-597