EconPapers    
Economics at your fingertips  
 

Design and evaluation of the crimping of a hooked self-expandable caval valve stent for the treatment of tricuspid regurgitation

Gideon Praveen Kumar, Hwa Liang Leo and Fangsen Cui

Computer Methods in Biomechanics and Biomedical Engineering, 2019, vol. 22, issue 5, 533-546

Abstract: To design a hooked self-expandable caval valve stent and determine the best crimping scenario for its percutaneous implantation in the Superior and Inferior Vena Cava (SVC & IVC) for the treatment of tricuspid regurgitation (TR). A hooked, Nitinol based stent design was modeled using SOLIDWORKS and finite element analysis (FEA) was carried out using ABAQUS. The Nitinol material used in this study was modeled in ABAQUS as superelastic-plastic. Two cases were simulated. In case A, the stent model was crimped to 18 F by compressing the stent main body and then: (i) bending both the proximal and distal hooks; (ii) straightening the proximal hooks and bending the distal hooks. In case B, the stent model was crimped to 18 F by: (i) bending the proximal and distal hooks and then compressing the stent main body; (ii) straightening the proximal hooks and bending the distal hooks and then compressing the stent main body. The maximum strain after crimping was used to evaluate the best crimping scenario. Hook straightening produced strains of 10.7% and 10.96% as opposed to 12.6% and 13.0% produced by hook bending. From comparison of results of both cases simulated, it was found that straightening the hooks gave lower strain and thus was the best crimping procedure. The analysis performed in this paper may help understand the critical issue of crimpability of the new stent design. The best crimping scenario can be found based on finite element modeling and simulation. Identifying the best crimping way will also help the design team to optimize the delivery system that will eventually be used to deploy this caval valve stent.

Date: 2019
References: Add references at CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2019.1569636 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:22:y:2019:i:5:p:533-546

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2019.1569636

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:22:y:2019:i:5:p:533-546