Using artificial neural networks to predict impingement and dislocation in total hip arthroplasty
D. Alastruey-López,
L. Ezquerra,
B. Seral and
M. A. Pérez
Computer Methods in Biomechanics and Biomedical Engineering, 2020, vol. 23, issue 10, 649-657
Abstract:
Dislocation after total hip arthroplasty (THA) remains a major issue and an important post-surgical complication. Impingement and subsequent dislocation are influenced by the design (head size) and position (anteversion and abduction angles) of the acetabulum and different movements of the patient, with external extension and internal flexion the most critical movements. The aim of this study is to develop a computational tool based on a three-dimensional (3D) parametric finite element (FE) model and an artificial neural network (ANN) to assist clinicians in identifying the optimal prosthesis design and position of the acetabular cup to reduce the probability of impingement and dislocation. A 3D parametric model of a THA was used. The model parameters were the femoral head size and the acetabulum abduction and anteversion angles. Simulations run with this parametric model were used to train an ANN, which predicts the range of movement (ROM) before impingement and dislocation. This study recreates different configurations and obtains absolute errors lower than 5.5° between the ROM obtained from the FE simulations and the ANN predictions. The ROM is also predicted for patients who had already suffered dislocation after THA, and the computational predictions confirm the patient’s dislocations. Summarising, the combination of a 3D parametric FE model of a THA and an ANN is a useful computational tool to predict the ROM allowed for different designs of prosthesis heads.
Date: 2020
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2020.1757661 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:23:y:2020:i:10:p:649-657
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2020.1757661
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().