Effect of gap outside contact area on lubrication of metal-on-Metal total hip replacement
Ali A. Al-Saffar and
Sam L. Evans
Computer Methods in Biomechanics and Biomedical Engineering, 2020, vol. 23, issue 11, 675-689
Abstract:
Ball-in-socket metal on metal (MOM) contacts were analysed using the Abaqus Finite Element package to simulate dry contact between the acetabular cup and the femoral head. Different cup thicknesses of 4, 6, 8, and 10 mm were considered using a polyurethane foam block support system. Elastohydrodynamic lubrication (EHL) analyses were developed for the contacts using three different approaches to specify the contact. These were (i) A simple model based on the radii of relative curvature, (ii) An equivalent contact model developed so that its dry contact area and maximum pressure replicated the values obtained from the FE analysis, and (iii) A modified version of (ii) that also ensured equivalence of the gap shape outside the contact area. Published in vivo information for the hip joint contact forces over the walking cycle was used to specify the operating conditions for the EHL analysis. The analysis method was found to be effective for all points of the walking cycle for cases where the cup thickness exceeded 5 mm and modelling approach (ii) was identified as satisfactory. For a cup thickness of 4 mm, membrane action began to emerge in the FE analyses so that such contacts behaved in a different way.
Date: 2020
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2020.1758679 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:23:y:2020:i:11:p:675-689
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2020.1758679
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().