EconPapers    
Economics at your fingertips  
 

Is it possible to detect a true rotation axis of the temporomandibular joint with common pantographic methods? A fundamental kinematic analysis

Albert Mehl

Computer Methods in Biomechanics and Biomedical Engineering, 2020, vol. 23, issue 9, 445-455

Abstract: The location of the terminal hinge axis of the temporomandibular joint is still a very wide-spread procedure in dentistry in order to replicate the movement in various articulator devices. Especially pantographic methods are claimed to provide accurate measurements and, additionally, are seen to be able to separate a pure rotation of the joint from a movement with an arbitrary combined shift and rotation. In the latter application, these methods were used in a lot of studies as a reference standard. The aim of this study was to analyze, whether common pantographic methods in general are able to distinguish between a pure rotation and a movement with rotational and translational portions. The mathematical proof of this analysis was done with theoretical kinematic considerations and compared with computer simulations. The results show for the first time that there exist combinations of rotational and translational movements of the temporomandibular joint which cannot be separated from pure rotational movements using actual pantographic methods. Even more, the consequence is a shifted location of the (combined) finite center (axis) of rotation in comparison to the true center (axis) of rotation: in case of a translational portion of only 1 mm, this is a displacement of around ±6 mm and, in case of 2 mm translation, a displacement of ±12 mm. This finding necessitates a critical reinterpretation of former studies using pantographic methods as a reference standard. Further, under some circumstances it may also affect the applicability of articulator concepts and the interpretation of functional signs.

Date: 2020
References: Add references at CitEc
Citations:

Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2020.1724975 (text/html)
Access to full text is restricted to subscribers.

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:23:y:2020:i:9:p:445-455

Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20

DOI: 10.1080/10255842.2020.1724975

Access Statistics for this article

Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton

More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().

 
Page updated 2025-03-20
Handle: RePEc:taf:gcmbxx:v:23:y:2020:i:9:p:445-455