Biomechanical analysis of reinstating buccally flared maxillary 2nd molars using 3D printing anchorage supports: a 3D finite element study
Yunchun Kuang,
Chunjuan Wang,
Bo Hu,
Ge Feng,
Chao Wang and
Jinlin Song
Computer Methods in Biomechanics and Biomedical Engineering, 2021, vol. 24, issue 10, 1085-1096
Abstract:
The buccally flared maxillary 2nd molar has certain consequences on oral function and health. However, existing methods have some degree of disadvantages, such as invasion, complexity and side effects. The objectives of this study were to design anchorage systems to correct buccally flared maxillary 2nd molars and analyze their biomechanical effects by 3-dimensional (3D) finite element analysis. Finite element (FE) models of the 3D tanspalatal arches (TPAs) and 3D splints with different thicknesses and force points were constructed. The stress distribution on teeth, the hydrostatic pressure on periodontal ligaments and the initial displacement of teeth were analyzed. A total of 18 FE models were constructed and analyzed. The stress concentrated on a single anchorage tooth, and the hydrostatic pressure and initial displacement of the anchorage tooth were greater than those of the malposed 2nd molar in the 3D splint anchorage system. The stress spread on all anchorage teeth and the hydrostatic pressure and initial displacement of the anchorage tooth were less than those of the malposed 2nd molar in the 3D TPA anchorage system. Theoretically, the 3D TPA was better than the 3D splint as an anchorage to correct the buccally flared 2nd molar. A combination of 0.8 mm of thickness and mesial force point provided the optimal conditions for the 3D TPA. Further clinical studies should be conducted to verify the effects of 3D appliances.
Date: 2021
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2020.1867850 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:24:y:2021:i:10:p:1085-1096
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2020.1867850
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().