A three-dimensional measurement based on CT for the posterior tilt with ideal inter-and intra-observer reliability in non-displaced femoral neck fractures
Shenghui Wu,
Wei Wang,
Binbin Zhang,
Haowei Zhang,
Xinsheng Xu,
Guangyi Li,
Huipeng Shi and
Jiong Mei
Computer Methods in Biomechanics and Biomedical Engineering, 2021, vol. 24, issue 16, 1854-1861
Abstract:
Posterior tilt is associated with prognosis of non-displaced femoral neck fractures (FNFs). Knowledge of their association is critical and informs surgeons whether to choose internal fixation or arthroplasty in treatment of non-displaced FNFs. This study aimed to design a novel three-dimensional (3D) posterior tilt measurement and evaluate the intra- and inter-observer variability compared to two-dimensional (2D) measurement proposed by Palm. We hypothesized that 3D measurement would be more accurate and realistic with higher reliability. To test the hypothesis, three observers measured the posterior tilt on the radiographs of 50 non-displaced FNFs, twice with both methods. Intra- and inter-observer reliability for each measurement method used were determined. The measured angle was divided into two categories, at the cut-off of 20° for clinical practice simulation. Intra- and inter-observer reliability were identified for clinical effectiveness. The results indicated that inter- and intra-observer reliability for 3D measurement and its classification was almost perfect with an intraclass coefficient of 0.995 (0.994) and a kappa value of 0.927(0.947), respectively. Conversely, a substantial inter- and intra-observer reliability for the 2D measurement was obtained with an interclass coefficient of 0.764 as well as an intraclass coefficient of 0.773. The clinical validity for 2D measurement showed slight inter-reliability and moderate intra-reliability with a kappa value of 0.192 and 0.587, respectively. Hence, the novel 3D measurement appears to be more reliable with a strong inter- and intra-observer reliability measurement. Further clinical studies are needed to carry out to validate this hypothesis.
Date: 2021
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2021.1925256 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:24:y:2021:i:16:p:1854-1861
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2021.1925256
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().