On the impact force analysis of two-leg landing with a flexed knee
Marzieh Mojaddarasil and
Mohammad Jafar Sadigh
Computer Methods in Biomechanics and Biomedical Engineering, 2021, vol. 24, issue 16, 1862-1875
Abstract:
This article looks into the effects of the initial knee flexion angle at the contact time on the peak of the impulsive lower limb forces during landing, and how these effects are related to muscular activities. The impact dynamics of drop landing is studied via a musculoskeletal model with eight Hill-type lower-limb muscles. A method is proposed for the representation of two landing strategies: landing with high and low joint stiffness. Then, in each landing strategy, the effect of the initial knee flexion angle on the peak ground reaction force (GRF), the peak knee ligaments force and the peak tibiofemoral contact force is investigated by considering different initial contact postures. It is observed that while landing with a flexed knee decreases the peak GRF in both landing strategies, it decreases the peak tibiofemoral and knee ligaments forces only in landing with low joint stiffness. Specifically, by increasing the initial knee flexion from 0° to 70°, the peak tibiofemoral and knee ligaments forces decrease monotonically by 54% and 82%, in landing with low joint stiffness. For high joint stiffness, however, as the initial knee flexion increases from 10° to 70°, the peak tibiofemoral force is seen to increase monotonically by 42% and the peak knee ligaments force is seen to have a non-monotonic behavior, first decreasing by 42%, and then, increasing by 250%. These results can be considered in training landing strategies to reduce the risk of knee injury.
Date: 2021
References: Add references at CitEc
Citations:
Downloads: (external link)
http://hdl.handle.net/10.1080/10255842.2021.1925257 (text/html)
Access to full text is restricted to subscribers.
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:taf:gcmbxx:v:24:y:2021:i:16:p:1862-1875
Ordering information: This journal article can be ordered from
http://www.tandfonline.com/pricing/journal/gcmb20
DOI: 10.1080/10255842.2021.1925257
Access Statistics for this article
Computer Methods in Biomechanics and Biomedical Engineering is currently edited by Director of Biomaterials John Middleton
More articles in Computer Methods in Biomechanics and Biomedical Engineering from Taylor & Francis Journals
Bibliographic data for series maintained by Chris Longhurst ().